APC Back-UPS Pro uninterruptible power supply (UPS) Line-Interactive 1.2 kVA 720 W 10 AC outlet(s)

APC Back-UPS Pro uninterruptible power supply (UPS) Line-Interactive 1.2 kVA 720 W 10 AC outlet(s)

720 Watts / 1200 VA, 230V / 230V

Trade Prices

Distributor Product SKU Stock Updated Price
Ingram Micro INTL BACK-UPS PRO 1200VA 230V DT8953 Register free see stock

Description

The Back-UPS RS offers high performance protection for your business and office computer systems. It provides abundant battery backup power, allowing you to work through medium and extended length power outages. It also safeguards your equipment from damaging surges and spikes that travel along utility, phone and network lines. A distinguishing feature of the Back-UPS RS is automatic voltage regulation (AVR). AVR instantly adjusts both low and high voltages to safe levels, so you can work indefinitely during brownouts and overvoltage situations, saving the battery for power outages when you need it most. Award-winning shutdown software automatically powers down your computer system in the event of an extended power outage. Additional features like audible alarms, LED status indicators, user replaceable battery, push-button circuit breakers and plentiful outlets (including transformer-block spaced outlets) make the Back-UPS RS the perfect unit to protect your business' productivity from the constant threat of power problems and lost data.

Green mode: Patent-pending operating mode that bypasses unused electrical components in good power conditions to achieve very high operating efficiency without sacrificing any protection.

Audible alarms: Provide notification of changing flywheel conditions

Battery failure notification: Provides early-warning fault analysis on batteries enabling timely preventive maintenance

Power-saving outlets: Automatically cuts power to idle equipment to conserve electricity.

LCD display: Alpha-Numeric Display which displays system parameters and alarms.

Battery-protected and surge-only outlets: Reserves power capacity and run time for connected equipment that require battery back-up while providing surge only protection for less critical equipment

Cold-start capable: Provides temporary battery power when the utility power is out.

Hot-swappable batteries: Ensures clean, uninterrupted power to protected equipment while batteries are being replaced

Automatic self-test: Periodic battery self-test ensures early detection of a battery that needs to be replaced.

Adjustable voltage sensitivity: Provides the ability to adapt the UPS for optimal performance in specific power environments or generator applications.

Audible alarms: Provides notification of changing utility power and UPS conditions.

User-replaceable batteries: Increases availability by allowing a trained user to perform upgrades and replacements of the batteries reducing Mean Time to Repair (MTTR)

USB connectivity: Provides management of the UPS via a USB port (not available on all models).

Transformer-block spaced outlets: Protect equipment with input transformer blocks without blocking access to other receptacles.

Boost and Trim Automatic Voltage Regulation (AVR): Gives higher application availability by correcting low and high voltage conditions without using the battery

Automatic Voltage Regulation (AVR): Gives higher application availability by correcting low and high voltage conditions without using the battery.

Intelligent battery management: Maximizes battery performance, life, and reliability through intelligent, precision charging.

Building Wiring Fault Indicator: This LED informs users of potentially dangerous wiring problems in the wall circuit.

Adjustable voltage sensitivity: Provides the ability to adapt the Power Conditioner for optimal performance in specific power environments or generator applications.

Automatic Voltage Regulation (AVR): Automatically steps up low voltage and steps down high voltage to levels that are suitable for your equipment.

Battery fault detection: Monitors room and individual battery temperature changes for early detection of thermal runaway, shorted cells, open circuit, and bad battery.

Battery-protected and surge-only outlets: Reserves power capacity and run time for connected equipment that require battery back-up while providing surge only protection for less critical equipment.

Safety-agency approved: Ensures the product has been tested and approved to work safely with the connected service provider equipment and within the specified environment.

Power conditioning: Protects connected loads from surges, spikes, lightning, and other power disturbances.

Audible alarms: Provides notification of changing utility power and UPS conditions.

Automatic restart of loads after UPS shutdown: Automatically starts up the connected equipment upon the return of utility power.

Automatic self-test: Periodic battery self-test ensures early detection of a battery that needs to be replaced.

Battery replacement without tools: Allows quick, easy battery replacement.

LED status indicators: Quickly understand unit and power status with visual indicators.

Cold-start capable: Provides temporary battery power when the utility power is out.

Hot-swappable batteries: Ensures clean, uninterrupted power to protected equipment while batteries are being replaced

Resettable circuit breakers: Enables a quick recovery from overload events.

Transformer-block spaced outlets: Protect equipment with input transformer blocks without blocking access to other receptacles.

User-replaceable batteries: Increases availability by allowing a trained user to perform upgrades and replacements of the batteries reducing Mean Time to Repair (MTTR)

Adjustable voltage sensitivity: Provides the ability to adapt the UPS for optimal performance in specific power environments or generator applications.

Adjustable voltage-transfer points: Maximizes useful battery life by widening the input voltage window or tightening the output voltage regulation.

Intelligent battery management: Micro-processor controlled battery charging and diagnostic testing ensures maximum battery life.

Specifications

Power
Output frequency regulation50/60 Hz
Output power720 W
Input operation voltage (min)156 V
Input operation voltage (max)300 V
Surge energy rating441 J
Efficiency98.8%
Crest factor3:1
Output power capacity1.2 kVA
Input frequency50/60 Hz
Battery
Battery typeAPCRBC124
Battery life (max)5 year(s)
Battery capacity187 VAh
Battery technologySealed Lead Acid (VRLA)
Battery recharge time8 h
Typical backup time at half load15.7 min
Typical backup time at full load5.4 min
Hot-swap batteryYes
Cold startYes
Automatic battery testYes
Replacement battery cartridge1
Performance
Hold time (min)10 ms
Hold time (max)12 ms
Audible alarm modesLow battery alarm, Overload alarm
UPS topologyLine-Interactive
WaveformSine
Automatic Voltage Regulation (AVR)Yes
Surge protectionYes
Surge protection featuresDigital Subscriber Line (DSL), Fax, Modem, Network, Telephone
Noise level45 dB
Audible alarm(s)Yes
Features
Hold time (min)10 ms
Hold time (max)12 ms
Audible alarm modesLow battery alarm, Overload alarm
UPS topologyLine-Interactive
WaveformSine
Output frequency regulation50/60 Hz
Automatic Voltage Regulation (AVR)Yes
Output power720 W
Input operation voltage (min)156 V
Input operation voltage (max)300 V
Surge energy rating441 J
Efficiency98.8%
Surge protectionYes
Surge protection featuresDigital Subscriber Line (DSL), Fax, Modem, Network, Telephone
Noise level45 dB
Crest factor3:1
Audible alarm(s)Yes
Output power capacity1.2 kVA
Input frequency50/60 Hz
Ports & interfaces
USB portYes
AC outlets quantity10 AC outlet(s)
AC outlet typesC13 coupler
Power plugC14 coupler
Number of output IEC jumpers2
Design
Product colourBlack
CertificationA-tick, C-tick, CE, GOST, GS Mark, Telepermit, TUV, REACH, PEP, EOLI
Display typeLCD
Operational conditions
Operating temperature (T-T)0 - 40 °C
Storage temperature (T-T)-15 - 45 °C
Operating relative humidity (H-H)0 - 95%
Storage relative humidity (H-H)0 - 95%
Operating altitude0 - 354330.7" (0 - 9000 m)
Non-operating altitude0 - 590551.2" (0 - 15000 m)
Technical details
Sustainability certificatesENERGY STAR
Harmonized System (HS) code85078000
Compliance certificatesRoHS
Weight & dimensions
Package width9.37" (238 mm)
Package depth19.2" (488 mm)
Package height15.2" (387 mm)
Weight25.6 lbs (11.6 kg)
Width4.41" (112 mm)
Package weight29.1 lbs (13.2 kg)
Height11.9" (301 mm)
Depth15" (380 mm)
Packaging data
ManualYes
Cables includedPhone (RJ-11), USB cable
Warranty cardYes
Software CDYes
Package width9.37" (238 mm)
Package depth19.2" (488 mm)
Package height15.2" (387 mm)
Bundled softwarePowerChute Personal Edition
Package weight29.1 lbs (13.2 kg)
Logistics data
Products per master (outer) case1 pc(s)
Products per pallet24 pc(s)
Harmonized System (HS) code85078000
Certificates
CertificationA-tick, C-tick, CE, GOST, GS Mark, Telepermit, TUV, REACH, PEP, EOLI
Other features
Battery typeAPCRBC124
Nominal output voltage230 V
Nominal input voltage230 V
Networking features10/100/1000 Base-T
Packaging content
ManualYes
Cables includedPhone (RJ-11), USB cable
Warranty cardYes
Software CDYes