14.5kW 3-Phase Monitored PDU - LX Platform, 30 C13 & 12 C19 Outlets (208/240V), Hubbell CS8365C, 0U, TAA
Offer details
Trade Prices
Distributor | Product | SKU | Stock | Updated | Price |
---|---|---|---|---|---|
Tripp Lite UPS PDU3EVN6H50BA 14.5kW 3-Phase Monitored PDU LX Platform Retail | 256160 | Register free see stock |
Related Products
- Power Cables
- Power Distribution Units (PDUs)
- Warranty & Support Extensions
- Temperature & Humidity Sensors
-
Category: Power Cables
-
Category: Power Cables
-
Category: Power Cables
-
Category: Power Cables
-
Category: Power Cables
-
Category: Power Cables
-
Category: Power Cables
-
Category: Power Cables
-
Category: Power Cables
-
Category: Power Cables
-
Category: Power Cables
-
Category: Power Cables
-
Category: Power Distribution Units (PDUs)
-
Category: Power Distribution Units (PDUs)
-
Category: Power Distribution Units (PDUs)
-
Category: Power Distribution Units (PDUs)
-
Category: Power Distribution Units (PDUs)
-
Category: Power Distribution Units (PDUs)
-
Category: Power Distribution Units (PDUs)
-
Category: Power Distribution Units (PDUs)
-
Category: Power Distribution Units (PDUs)
-
Category: Power Distribution Units (PDUs)
-
Category: Power Distribution Units (PDUs)
-
Category: Power Distribution Units (PDUs)
-
Category: Power Distribution Units (PDUs)
-
Category: Power Distribution Units (PDUs)
-
Category: Power Distribution Units (PDUs)
-
Category: Power Distribution Units (PDUs)
-
Category: Power Distribution Units (PDUs)
-
Category: Power Distribution Units (PDUs)
-
Category: Power Distribution Units (PDUs)
-
Category: Power Distribution Units (PDUs)
-
Category: Power Distribution Units (PDUs)
-
Category: Power Distribution Units (PDUs)
-
Category: Power Distribution Units (PDUs)
-
Category: Power Distribution Units (PDUs)
-
Category: Power Distribution Units (PDUs)
-
Category: Power Distribution Units (PDUs)
-
Category: Power Distribution Units (PDUs)
-
Category: Power Distribution Units (PDUs)
-
Category: Power Distribution Units (PDUs)
-
Category: Power Distribution Units (PDUs)
-
Category: Power Distribution Units (PDUs)
-
Category: Power Distribution Units (PDUs)
-
Category: Power Distribution Units (PDUs)
-
Category: Power Distribution Units (PDUs)
-
Category: Power Distribution Units (PDUs)
-
Category: Power Distribution Units (PDUs)
-
Category: Power Distribution Units (PDUs)
-
Category: Power Distribution Units (PDUs)
-
Category: Power Distribution Units (PDUs)
-
Category: Power Distribution Units (PDUs)
-
Category: Power Distribution Units (PDUs)
-
Category: Power Distribution Units (PDUs)
-
Category: Power Distribution Units (PDUs)
-
Category: Power Distribution Units (PDUs)
-
Category: Power Distribution Units (PDUs)
-
Category: Power Distribution Units (PDUs)
-
Category: Power Distribution Units (PDUs)
-
Category: Power Distribution Units (PDUs)
-
Category: Power Distribution Units (PDUs)
-
Category: Power Distribution Units (PDUs)
-
Category: Power Distribution Units (PDUs)
-
Category: Power Distribution Units (PDUs)
-
Category: Power Distribution Units (PDUs)
-
Category: Power Distribution Units (PDUs)
-
Category: Power Distribution Units (PDUs)
-
Category: Power Distribution Units (PDUs)
-
Category: Power Distribution Units (PDUs)
-
Category: Power Distribution Units (PDUs)
-
Category: Power Distribution Units (PDUs)
-
Category: Power Distribution Units (PDUs)
-
Category: Power Distribution Units (PDUs)
-
Category: Power Distribution Units (PDUs)
-
Category: Power Distribution Units (PDUs)
-
Category: Power Distribution Units (PDUs)
-
Category: Power Distribution Units (PDUs)
-
Category: Power Distribution Units (PDUs)
-
Category: Power Distribution Units (PDUs)
-
Category: Power Distribution Units (PDUs)
-
Category: Power Distribution Units (PDUs)
-
Category: Power Distribution Units (PDUs)
-
Category: Power Distribution Units (PDUs)
-
Category: Power Distribution Units (PDUs)
-
Category: Power Distribution Units (PDUs)
-
Category: Power Distribution Units (PDUs)
-
Category: Power Distribution Units (PDUs)
-
Category: Power Distribution Units (PDUs)
-
Category: Power Distribution Units (PDUs)
-
Category: Power Distribution Units (PDUs)
-
Category: Power Distribution Units (PDUs)
-
Category: Power Distribution Units (PDUs)
-
Category: Power Distribution Units (PDUs)
-
Category: Power Distribution Units (PDUs)
-
Category: Power Distribution Units (PDUs)
-
Category: Power Distribution Units (PDUs)
-
Category: Power Distribution Units (PDUs)
-
Category: Power Distribution Units (PDUs)
-
Category: Power Distribution Units (PDUs)
-
Category: Power Distribution Units (PDUs)
-
Category: Power Distribution Units (PDUs)
-
Category: Power Distribution Units (PDUs)
-
Category: Power Distribution Units (PDUs)
-
Category: Power Distribution Units (PDUs)
-
Category: Power Distribution Units (PDUs)
-
Category: Power Distribution Units (PDUs)
-
Category: Power Distribution Units (PDUs)
-
Category: Power Distribution Units (PDUs)
-
Category: Power Distribution Units (PDUs)
-
Category: Power Distribution Units (PDUs)
-
Category: Power Distribution Units (PDUs)
-
Category: Power Distribution Units (PDUs)
-
Category: Power Distribution Units (PDUs)
-
Category: Power Distribution Units (PDUs)
-
Category: Power Distribution Units (PDUs)
-
Category: Power Distribution Units (PDUs)
-
Category: Power Distribution Units (PDUs)
-
Category: Power Distribution Units (PDUs)
-
Category: Warranty & Support Extensions
-
Category: Warranty & Support Extensions
-
Category: Warranty & Support Extensions
-
Category: Temperature & Humidity Sensors
-
Category: Temperature & Humidity Sensors
-
Category: Temperature & Humidity Sensors
Description
14.5kW 3-Phase PDU Distributes and Monitors Network-Grade Power
This monitored PDU provides real-time remote monitoring of voltage and load levels via its built-in network interface. Ideal for data centers, server rooms and high-density network closets, the PDU3EVN6H50BA features 30 C13 and 12 C19 208/240V outlets in three breakered load banks, which distribute AC power to rack equipment. The banks can be individually monitored to ensure proper load balance and prevent downtime. Plug-lock insert sleeves are included to prevent connected cables from becoming accidentally dislodged.
Built-In LX Platform Network Management Card Allows Remote Access 24/7
The Java-free HTML5-based LX Platform network interface enables full remote access for PDU status monitoring and email notifications via secure web browser, SNMP, telnet or SSH. It supports 10/100/1000 Mbps auto-sensing for optimum communication with an Ethernet network. Optional EnviroSense2 modules (sold separately) provide a variety of environmental monitoring capabilities. Protocols supported include IPv4, IPv6, HTTP, HTTPS, SMTP, SNMPv1, SNMPv2, SNMPv3, telnet, SSH, FTP, DHCP and NTP. The monitored PDU can receive IP address assignments via DHCP server (automatic) or static (manual) method.
Color Touchscreen LCD Offers Important Data at a Glance
An easy-to-navigate color touchscreen LCD reports network data, including IP address, input current level per phase, and output current per load bank with ±1% billing-grade accuracy. It also generates a unique QR code to allow read-only access to the 0U PDU via mobile device. If an EnviroSense2 module is connected to the 3-phase PDU, the LCD also displays status and environmental data, such as temperature and humidity.
Easy to Install Vertically in an EIA-Standard 19 in. Rack
The 70-inch 0U PDU mounts vertically using the included toolless mounting buttons or the included rack-mounting brackets. Spare buttons are also included. Use the included PDUMVROTATEBRKT kit to install the PDU with outlets facing the rear for better airflow or equipment access. A six-foot cord with Hubbell CS8365C 208/240V 3-phase input connects the PDU to a compatible AC power source, generator or protected UPS.
TAA-Compliant for GSA Schedule Purchases
The PDU3EVN6H50BA is compliant with the Federal Trade Agreements Act (TAA), which makes it eligible for GSA (General Services Administration) Schedule and other federal procurement contracts.
Typical Applications
- Power mission-critical rack equipment in a data center, computer room or high-density network closet in a government, commercial or industrial facility
- Monitor power loads from various computers, switches, servers and other networking equipment
Package Includes
- PDU3EVN6H50BA 14.5kW 3-Phase Monitored PDU
- Built-in LX Platform interface
- Configuration cable
- (42) Plug-lock insert sleeves
- Rack-mounting hardware
- Spare mounting buttons
- PDUMVROTATEBRKT mounting bracket accessory
- Owner’s manual
This monitored PDU provides real-time remote monitoring of voltage and load levels via its built-in network interface. Ideal for data centers, server rooms and high-density network closets, the PDU3EVN6H50BA features 30 C13 and 12 C19 208/240V outlets in three breakered load banks, which distribute AC power to rack equipment. The banks can be individually monitored to ensure proper load balance and prevent downtime. Plug-lock insert sleeves are included to prevent connected cables from becoming accidentally dislodged.
Built-In LX Platform Network Management Card Allows Remote Access 24/7
The Java-free HTML5-based LX Platform network interface enables full remote access for PDU status monitoring and email notifications via secure web browser, SNMP, telnet or SSH. It supports 10/100/1000 Mbps auto-sensing for optimum communication with an Ethernet network. Optional EnviroSense2 modules (sold separately) provide a variety of environmental monitoring capabilities. Protocols supported include IPv4, IPv6, HTTP, HTTPS, SMTP, SNMPv1, SNMPv2, SNMPv3, telnet, SSH, FTP, DHCP and NTP. The monitored PDU can receive IP address assignments via DHCP server (automatic) or static (manual) method.
Color Touchscreen LCD Offers Important Data at a Glance
An easy-to-navigate color touchscreen LCD reports network data, including IP address, input current level per phase, and output current per load bank with ±1% billing-grade accuracy. It also generates a unique QR code to allow read-only access to the 0U PDU via mobile device. If an EnviroSense2 module is connected to the 3-phase PDU, the LCD also displays status and environmental data, such as temperature and humidity.
Easy to Install Vertically in an EIA-Standard 19 in. Rack
The 70-inch 0U PDU mounts vertically using the included toolless mounting buttons or the included rack-mounting brackets. Spare buttons are also included. Use the included PDUMVROTATEBRKT kit to install the PDU with outlets facing the rear for better airflow or equipment access. A six-foot cord with Hubbell CS8365C 208/240V 3-phase input connects the PDU to a compatible AC power source, generator or protected UPS.
TAA-Compliant for GSA Schedule Purchases
The PDU3EVN6H50BA is compliant with the Federal Trade Agreements Act (TAA), which makes it eligible for GSA (General Services Administration) Schedule and other federal procurement contracts.
Typical Applications
- Power mission-critical rack equipment in a data center, computer room or high-density network closet in a government, commercial or industrial facility
- Monitor power loads from various computers, switches, servers and other networking equipment
Package Includes
- PDU3EVN6H50BA 14.5kW 3-Phase Monitored PDU
- Built-in LX Platform interface
- Configuration cable
- (42) Plug-lock insert sleeves
- Rack-mounting hardware
- Spare mounting buttons
- PDUMVROTATEBRKT mounting bracket accessory
- Owner’s manual
Specifications
Design | |
---|---|
Type | Three-phase |
PDU types | Monitored |
Mounting | Vertical |
Display | LCD |
Product colour | Black, Gray |
Certification | UL60950-1: 2007 R10.14, CAN/CSA-C22.2 NO. 60950-1-07+A1: 2011+A2: 2014, NOM, FCC Class A Part 15, TAA |
Rack capacity | 0U |
Housing material | Metal |
Ports & interfaces | |
AC outlets quantity | 42 AC outlet(s) |
AC outlet types | C13 coupler, C19 coupler |
Power plug | CS8365C |
Features | |
Cable length | 70.9" (1.8 m) |
Certification | UL60950-1: 2007 R10.14, CAN/CSA-C22.2 NO. 60950-1-07+A1: 2011+A2: 2014, NOM, FCC Class A Part 15, TAA |
Colour-coded outlets | Yes |
Security algorithms | SNMP |
Ergonomics | |
Cable length | 70.9" (1.8 m) |
Display | LCD |
Power | |
Maximum power | 14500 W |
Nominal input voltage | 208; 240 V |
Nominal output voltage | 208; 240 V |
Power protection features | Overload |
Maximum current | 35 A |
AC input frequency | 50 - 60 Hz |
Weight & dimensions | |
Weight | 12.9 lbs (5.83 kg) |
Width | 2.17" (55.1 mm) |
Depth | 2.52" (64 mm) |
Height | 70" (1778 mm) |
Package width | 9.65" (245.1 mm) |
Package depth | 75.9" (1927.1 mm) |
Package height | 6.89" (175 mm) |
Package weight | 25.1 lbs (11.4 kg) |
Packaging data | |
Package width | 9.65" (245.1 mm) |
Package depth | 75.9" (1927.1 mm) |
Package height | 6.89" (175 mm) |
Package weight | 25.1 lbs (11.4 kg) |
Operational conditions | |
Operating temperature (T-T) | 0 - 50 °C |
Storage temperature (T-T) | -30 - 60 °C |
Operating relative humidity (H-H) | 5 - 95% |
Operating temperature (T-T) | 32 - 122 °F |
Operating altitude | 0 - 118110.2" (0 - 3000 m) |
Technical details | |
Compliance certificates | RoHS |
Security | |
Security algorithms | SNMP |
Logistics data | |
Products per master (outer) case | 1 pc(s) |
Country of origin | Taiwan |