Tripp Lite PDUB30 power distribution unit (PDU) 7 AC outlet(s) 2U Black

Tripp Lite PDUB30 power distribution unit (PDU) 7 AC outlet(s) 2U Black

2.9kW Single-Phase Hot-Swap PDU, 120V 30A (1 L5-30R, 6 5-15/20R), 2 L5-30P, 10ft & 6ft Cords, 2U Rack-Mount

Trade Prices

Distributor Product SKU Stock Updated Price
BlueStar TRIPP LITE, EOL, REPLACED BY PDUMH30AT, POWER DISTRIBUTION UNIT DUAL SOURCE HOT SWAP 100-127V 24A 5-15/20R & L5-30R 7 OUT 2U RM PDUB30 Register free see stock

Related Products

Description

Tripp Lite’s Hot-swap PDU systems enable live-replacement of standard UPS systems for maintenance with no interruption of connected server or networking loads. Dual input power cables support PDU connection to separate Utility and UPS power sources. Manual transfer switch with lighted status indicators controls the source of power to connected equipment between Utility and UPS. Set the switch to UPS during normal operation and connected equipment will receive full-time conditioned power from the UPS. Set the switch to Utility to momentarily power connected equipment from the Utility line cord and bypass the UPS while the UPS system is removed and replaced with a fresh one. Once the new UPS is up and running with all data and electrical connections restored, set the switch back to the UPS setting to once again provide fully-conditioned UPS power to connected equipment.
- Tripp Lite Hot-swap PDU systems support live-replacement of standard UPS systems for maintenance with no interruption of connected server or networking loads
- PDUB30 is universally compatible with any Tripp Lite or other brand of 100-127V UPS rated up to 3000VA or 2880 watts with a NEMA L5-30P input cable
- 2U horizontal rackmount form factor compatible with 2 or 4 post racks
- Supports space saving rear-post mounting in the same rack space as many Tripp Lite Rackmount UPS systems (select installations, see manual)
- Pair of attached L5-30P PDU input cables connect to separate Utility and UPS power sources
- 6 5-15/20R and 1 L5-30R outlets support critical networking loads in both Utility and UPS operating modes
- One additional L5-30R pass-through outlet supports UPS input power cord
- Dual input power cables support PDU connection to separate Utility and UPS power sources
- Manual transfer switch with lighted status indicators controls the source of power to connected equipment between Utility and UPS
- Set the switch to UPS during normal operation and connected equipment will receive full-time conditioned power from the UPS
- Set the switch to Utility to bypass the UPS and provide connected equipment with unfiltered power directly from the Utility line cord while the UPS system is removed and replaced with a fresh one
- Once the new UPS is up and running with all connections restored, set the switch back to the UPS setting to once again provide fully-conditioned UPS power to connected equipment
- TAA Compliant Version Available - Order Tripp Lite PDUB30TAA

Specifications

Design
PDU typesBasic
MountingHorizontal
Product colourBlack
CertificationUL60950, CSA
Rack capacity2U
Housing materialMetal
Ports & interfaces
AC outlets quantity7 AC outlet(s)
AC outlet typesNEMA 5–15, NEMA 5–20R, NEMA L5-30R
Power plugNEMA L5-30P
Features
LED indicatorsYes
CertificationUL60950, CSA
Ergonomics
LED indicatorsYes
Power
Nominal input voltage100-127 V
Nominal output voltage100-127 V
Maximum current24 A
AC input frequency50 - 60 Hz
Weight & dimensions
Dimensions (WxDxH)17.3 x 3.03 x 3.43" (440 x 77 x 87 mm)
Weight7.72 lbs (3.5 kg)
Operational conditions
Storage temperature (T-T)-15 - 50 °C
Operating altitude0 - 118110.2" (0 - 3000 m)
Technical details
Compliance certificatesRoHS