Tripp Lite SUINT1000LCD2U uninterruptible power supply (UPS) Double-conversion (Online) 1 kVA 900 W 6 AC outlet(s)
- Brand: Tripp Lite
- Category:
- SKU: SUINT1000LCD2U
- EAN: 0037332185648
SmartOnline 1000VA 900W 208/230V Double-Conversion UPS - 8 Outlets, Extended Run, Network Card Option, LCD, USB, DB9, 2U Rack/Tower
Offer details
Trade Prices
Description
Double-Conversion UPS Protects Equipment Against Damage, Downtime and Data Loss
This on-line double-conversion UPS system maintains perfect output by converting AC input to DC, then reconverting UPS output to fully regulated sine wave AC. Constant on-line operation completely isolates sensitive equipment from every power problem on the AC line. The SmartOnline® SUINT1000LCD2U provides the highest level of power protection and battery backup for education, healthcare, military, government and other mission-critical IT applications where space is limited, but premium power reliability is essential.
Reliable, Expandable Battery Backup Keeps You Operational Through Power Outages
The field-replaceable, hot-swappable VRLA battery modules allow you to work through short power failures and give you enough time to safely save files and shut down your system in case of a prolonged blackout. Zero transfer time between on-line and battery modes maintains continuous operation of connected equipment without interruption or rebooting. Extra runtime is available by connecting up to four optional extended battery modules (BP48RT, sold separately).
Optional LX Platform Network Management Card Allows Remote Access 24/7
The WEBCARDLXE network interface (sold separately) enables full remote configuration and management, including load shedding, reboots of connected equipment and safe shutdowns. The IP-based Auto Probe feature ensures continuous network uptime by communicating with other network devices, detecting lost connectivity and automatically rebooting IT equipment. Optional EnviroSense2 modules (E2MT, E2MTDO and E2MTHDI, all sold separately) provide a variety of environmental monitoring and control options.
C13 Outlets Protect Your Connected Components
Eight C13 outlets provide connected equipment with pure sine wave AC output and allow you to manage power consumption down to the outlet group level. Power provided by these outlets is filtered to protect connected equipment against damaging surges and line noise. Four outlets are grouped into two load banks that let you shed non-critical loads to extend runtime for critical loads.
Premium Protection from EMI/RFI Line Noise Helps Your Equipment Perform Better
This UPS system filters out disruptive electromagnetic and radio frequency interference that can inflict hardware damage or data loss. This EMI/RFI filtering also helps your connected components perform better and last longer.
ENERGY STAR-Certified to Help You Save Money and Protect the Environment
By meeting strict U.S. Department of Energy and U.S. Environmental Protection Agency requirements, this ENERGY STAR 2.0 UPS system provides high operational efficiency to signal a reduction in BTU emissions, save on utility and cooling costs and help protect the environment.
Clear LCD Interface Keeps You Informed at a Glance
The menu-driven front-panel LCD provides detailed alarms and notifications to help diagnose any issues. It provides system status, event logs, battery and power module status, usage analytics, serial number, firmware update info and more. Audible alarms can be disabled through the front menu when the UPS goes to battery power. The LCD rotates to accommodate both rack-mount and tower installation.
Advanced Communications Ports Allow for Automatic Saves and Shutdowns
RS-232 and USB ports connect to a device for a variety of communication options (cables are included). A dry-contact relay port can be programmed through the LCD to provide reliable communications to automation and industrial components. The RPO/ROO port permits emergency shutdown or remote restart of all connected equipment.
Versatile Installation Options
You can mount the SUINT1000LCD2U in just 2U of space in an EIA-standard 19-inch rack using the included hardware. You can also adapt it for tower installation using the included support stands. The C14 power inlet accepts a variety of user-supplied input cords.
This on-line double-conversion UPS system maintains perfect output by converting AC input to DC, then reconverting UPS output to fully regulated sine wave AC. Constant on-line operation completely isolates sensitive equipment from every power problem on the AC line. The SmartOnline® SUINT1000LCD2U provides the highest level of power protection and battery backup for education, healthcare, military, government and other mission-critical IT applications where space is limited, but premium power reliability is essential.
Reliable, Expandable Battery Backup Keeps You Operational Through Power Outages
The field-replaceable, hot-swappable VRLA battery modules allow you to work through short power failures and give you enough time to safely save files and shut down your system in case of a prolonged blackout. Zero transfer time between on-line and battery modes maintains continuous operation of connected equipment without interruption or rebooting. Extra runtime is available by connecting up to four optional extended battery modules (BP48RT, sold separately).
Optional LX Platform Network Management Card Allows Remote Access 24/7
The WEBCARDLXE network interface (sold separately) enables full remote configuration and management, including load shedding, reboots of connected equipment and safe shutdowns. The IP-based Auto Probe feature ensures continuous network uptime by communicating with other network devices, detecting lost connectivity and automatically rebooting IT equipment. Optional EnviroSense2 modules (E2MT, E2MTDO and E2MTHDI, all sold separately) provide a variety of environmental monitoring and control options.
C13 Outlets Protect Your Connected Components
Eight C13 outlets provide connected equipment with pure sine wave AC output and allow you to manage power consumption down to the outlet group level. Power provided by these outlets is filtered to protect connected equipment against damaging surges and line noise. Four outlets are grouped into two load banks that let you shed non-critical loads to extend runtime for critical loads.
Premium Protection from EMI/RFI Line Noise Helps Your Equipment Perform Better
This UPS system filters out disruptive electromagnetic and radio frequency interference that can inflict hardware damage or data loss. This EMI/RFI filtering also helps your connected components perform better and last longer.
ENERGY STAR-Certified to Help You Save Money and Protect the Environment
By meeting strict U.S. Department of Energy and U.S. Environmental Protection Agency requirements, this ENERGY STAR 2.0 UPS system provides high operational efficiency to signal a reduction in BTU emissions, save on utility and cooling costs and help protect the environment.
Clear LCD Interface Keeps You Informed at a Glance
The menu-driven front-panel LCD provides detailed alarms and notifications to help diagnose any issues. It provides system status, event logs, battery and power module status, usage analytics, serial number, firmware update info and more. Audible alarms can be disabled through the front menu when the UPS goes to battery power. The LCD rotates to accommodate both rack-mount and tower installation.
Advanced Communications Ports Allow for Automatic Saves and Shutdowns
RS-232 and USB ports connect to a device for a variety of communication options (cables are included). A dry-contact relay port can be programmed through the LCD to provide reliable communications to automation and industrial components. The RPO/ROO port permits emergency shutdown or remote restart of all connected equipment.
Versatile Installation Options
You can mount the SUINT1000LCD2U in just 2U of space in an EIA-standard 19-inch rack using the included hardware. You can also adapt it for tower installation using the included support stands. The C14 power inlet accepts a variety of user-supplied input cords.
Specifications
| Power | |
|---|---|
| Output voltage regulation | 2% |
| Output power | 900 W |
| Input operation voltage (min) | 200 V |
| Input operation voltage (max) | 240 V |
| Output operation voltage (min) | 200 V |
| Output operation voltage (max) | 240 V |
| Surge energy rating | 627 J |
| Maximum current | 4.99 A |
| Efficiency | 93% |
| Output power capacity | 1 kVA |
| Input frequency | 50/60 Hz |
| Performance | |
| Audible alarm modes | Fault, Low battery alarm, Overload alarm |
| UPS topology | Double-conversion (Online) |
| Waveform | Sine |
| Number of input phases | 1 |
| LED indicators | Yes |
| EMI/RFI noise filtering | Yes |
| Surge protection | Yes |
| Power protection features | Over voltage, Under voltage |
| Noise level | 45 dB |
| Audible alarm(s) | Yes |
| Features | |
| Country of origin | China |
| Audible alarm modes | Fault, Low battery alarm, Overload alarm |
| UPS topology | Double-conversion (Online) |
| Waveform | Sine |
| Output voltage regulation | 2% |
| Number of input phases | 1 |
| Output power | 900 W |
| Input operation voltage (min) | 200 V |
| Input operation voltage (max) | 240 V |
| Output operation voltage (min) | 200 V |
| Output operation voltage (max) | 240 V |
| Surge energy rating | 627 J |
| Maximum current | 4.99 A |
| Efficiency | 93% |
| EMI/RFI noise filtering | Yes |
| Surge protection | Yes |
| Power protection features | Over voltage, Under voltage |
| Noise level | 45 dB |
| Audible alarm(s) | Yes |
| Output power capacity | 1 kVA |
| Input frequency | 50/60 Hz |
| Ports & interfaces | |
| AC outlets quantity | 6 AC outlet(s) |
| AC outlet types | C13 coupler, C14 coupler |
| Battery | |
| Typical backup time at half load | 12.3 min |
| Typical backup time at full load | 4.7 min |
| Hot-swap battery | Yes |
| Cold start | Yes |
| Design | |
| Country of origin | China |
| Rack capacity | 2U |
| Form factor | Rackmount |
| LED indicators | Yes |
| Product colour | Black |
| Cooling type | Active |
| Housing material | Metal |
| Display type | LCD |
| Operational conditions | |
| Operating temperature (T-T) | 0 - 40 °C |
| Storage temperature (T-T) | -15 - 50 °C |
| Operating relative humidity (H-H) | 5 - 95% |
| Storage relative humidity (H-H) | 5 - 95% |
| Technical details | |
| Sustainability certificates | ENERGY STAR |
| Compliance certificates | RoHS |
| Certificates | |
| Compliance certificates | RoHS |
| Packaging content | |
| Manual | Yes |
| Cables included | Input power cable, Output power cable, USB cable |
| Cooling | |
| Cooling type | Active |
| Sustainability | |
| Sustainability certificates | ENERGY STAR |
| Weight & dimensions | |
| Package width | 19.8" (502.9 mm) |
| Package depth | 23.5" (596.9 mm) |
| Package height | 9.6" (243.8 mm) |
| Weight | 28 lbs (12.7 kg) |
| Width | 17.2" (437.9 mm) |
| Package weight | 44.1 lbs (20 kg) |
| Height | 3.46" (87.9 mm) |
| Depth | 15.6" (397 mm) |
| Packaging data | |
| Manual | Yes |
| Cables included | Input power cable, Output power cable, USB cable |
| Package width | 19.8" (502.9 mm) |
| Package depth | 23.5" (596.9 mm) |
| Package height | 9.6" (243.8 mm) |
| Package weight | 44.1 lbs (20 kg) |
| Logistics data | |
| Country of origin | China |
| Products per master (outer) case | 1 pc(s) |
| Master (outer) case width | 19.8" (502.9 mm) |
| Master (outer) case length | 23.5" (596.9 mm) |
| Master (outer) case height | 9.6" (243.8 mm) |
| Master (outer) case gross weight | 44.1 lbs (20 kg) |