Tripp Lite PDUMNH20AT1 power distribution unit (PDU) 16 AC outlet(s) 1U Black
- Brand: Tripp Lite
- Category:
- SKU: PDUMNH20AT1
- EAN: 0037332267153
- Sell Price:
- Contract No:
- Account price:
1.92kW 120V Single-Phase ATS/Monitored PDU - 16 5-15/20R Outlets, Dual L5-20P/5-20P Inputs, 12 ft. Cords, 1U, TAA
Offer details
Trade Prices
Distributor | Product | SKU | Stock | Updated | Price |
---|---|---|---|---|---|
PDU ATS /MONITORED 16 5-15/20R | PDUMNH20AT1 | Register free see stock | |||
PDU ATS / MONITORED 120V 1.92KW | 9HC109 | ||||
ATS/MONITORED PDU 1.92KW 1U 16 5-15/20R | 6335948 |
Related Products
- Power Cables
- Power Distribution Units (PDUs)
- Warranty & Support Extensions
- UPS Accessories
- Temperature & Humidity Sensors
- Water Detectors
-
Category: Power Cables
-
Category: Power Cables
-
Category: Power Cables
-
Category: Power Cables
-
Category: Power Cables
-
Category: Power Cables
-
Category: Power Cables
-
Category: Power Cables
-
Category: Power Cables
-
Category: Power Cables
-
Category: Power Cables
-
Category: Power Cables
-
Category: Power Cables
-
Category: Power Cables
-
Category: Power Cables
-
Category: Power Cables
-
Category: Power Cables
-
Category: Power Cables
-
Category: Power Cables
-
Category: Power Cables
-
Category: Power Distribution Units (PDUs)
-
Category: Power Distribution Units (PDUs)
-
Category: Power Distribution Units (PDUs)
-
Category: Power Distribution Units (PDUs)
-
Category: Power Distribution Units (PDUs)
-
Category: Power Distribution Units (PDUs)
-
Category: Power Distribution Units (PDUs)
-
Category: Power Distribution Units (PDUs)
-
Category: Power Distribution Units (PDUs)
-
Category: Power Distribution Units (PDUs)
-
Category: Power Distribution Units (PDUs)
-
Category: Power Distribution Units (PDUs)
-
Category: Power Distribution Units (PDUs)
-
Category: Power Distribution Units (PDUs)
-
Category: Power Distribution Units (PDUs)
-
Category: Power Distribution Units (PDUs)
-
Category: Power Distribution Units (PDUs)
-
Category: Power Distribution Units (PDUs)
-
Category: Power Distribution Units (PDUs)
-
Category: Power Distribution Units (PDUs)
-
Category: Power Distribution Units (PDUs)
-
Category: Power Distribution Units (PDUs)
-
Category: Power Distribution Units (PDUs)
-
Category: Power Distribution Units (PDUs)
-
Category: Power Distribution Units (PDUs)
-
Category: Power Distribution Units (PDUs)
-
Category: Power Distribution Units (PDUs)
-
Category: Power Distribution Units (PDUs)
-
Category: Power Distribution Units (PDUs)
-
Category: Power Distribution Units (PDUs)
-
Category: Power Distribution Units (PDUs)
-
Category: Power Distribution Units (PDUs)
-
Category: Power Distribution Units (PDUs)
-
Category: Power Distribution Units (PDUs)
-
Category: Power Distribution Units (PDUs)
-
Category: Power Distribution Units (PDUs)
-
Category: Power Distribution Units (PDUs)
-
Category: Power Distribution Units (PDUs)
-
Category: Power Distribution Units (PDUs)
-
Category: Power Distribution Units (PDUs)
-
Category: Power Distribution Units (PDUs)
-
Category: Power Distribution Units (PDUs)
-
Category: Power Distribution Units (PDUs)
-
Category: Power Distribution Units (PDUs)
-
Category: Power Distribution Units (PDUs)
-
Category: Power Distribution Units (PDUs)
-
Category: Power Distribution Units (PDUs)
-
Category: Power Distribution Units (PDUs)
-
Category: Power Distribution Units (PDUs)
-
Category: Power Distribution Units (PDUs)
-
Category: Power Distribution Units (PDUs)
-
Category: Power Distribution Units (PDUs)
-
Category: Power Distribution Units (PDUs)
-
Category: Power Distribution Units (PDUs)
-
Category: Power Distribution Units (PDUs)
-
Category: Power Distribution Units (PDUs)
-
Category: Power Distribution Units (PDUs)
-
Category: Power Distribution Units (PDUs)
-
Category: Power Distribution Units (PDUs)
-
Category: Power Distribution Units (PDUs)
-
Category: Power Distribution Units (PDUs)
-
Category: Power Distribution Units (PDUs)
-
Category: Power Distribution Units (PDUs)
-
Category: Power Distribution Units (PDUs)
-
Category: Power Distribution Units (PDUs)
-
Category: Power Distribution Units (PDUs)
-
Category: Power Distribution Units (PDUs)
-
Category: Power Distribution Units (PDUs)
-
Category: Power Distribution Units (PDUs)
-
Category: Power Distribution Units (PDUs)
-
Category: Power Distribution Units (PDUs)
-
Category: Power Distribution Units (PDUs)
-
Category: Power Distribution Units (PDUs)
-
Category: Power Distribution Units (PDUs)
-
Category: Power Distribution Units (PDUs)
-
Category: Power Distribution Units (PDUs)
-
Category: Power Distribution Units (PDUs)
-
Category: Power Distribution Units (PDUs)
-
Category: Power Distribution Units (PDUs)
-
Category: Power Distribution Units (PDUs)
-
Category: Power Distribution Units (PDUs)
-
Category: Power Distribution Units (PDUs)
-
Category: Power Distribution Units (PDUs)
-
Category: Power Distribution Units (PDUs)
-
Category: Power Distribution Units (PDUs)
-
Category: Power Distribution Units (PDUs)
-
Category: Power Distribution Units (PDUs)
-
Category: Power Distribution Units (PDUs)
-
Category: Power Distribution Units (PDUs)
-
Category: Power Distribution Units (PDUs)
-
Category: Power Distribution Units (PDUs)
-
Category: Power Distribution Units (PDUs)
-
Category: Power Distribution Units (PDUs)
-
Category: Power Distribution Units (PDUs)
-
Category: Power Distribution Units (PDUs)
-
Category: Power Distribution Units (PDUs)
-
Category: Warranty & Support Extensions
-
Category: Warranty & Support Extensions
-
Category: Warranty & Support Extensions
-
Category: Temperature & Humidity Sensors
-
Category: Temperature & Humidity Sensors
-
Category: Temperature & Humidity Sensors
Description
Single-Phase 20A ATS PDU Distributes and Monitors Network-Grade Power in Real Time
This monitored PDU provides real-time remote monitoring of voltage, frequency and load levels via its built-in network interface. Ideal for network IT applications, small computer rooms and other equipment rack applications, the PDUMNH20AT1 features 16 NEMA 5-15/20R 120V outlets for connecting equipment. Dual 12-foot (3.7-meter) power cords with NEMA L5-20P inputs (two 5-20P adapters are included) connect to separate primary and secondary mains circuits, backup generators, UPS systems or utility power grids, including out-of-phase sources.
Switches from Primary to Secondary Power Source in Milliseconds
Automatic transfer switching (ATS) allows the PDU to switch to the secondary source within 2–7 milliseconds, should the primary source fail or become unstable, to ensure your connected equipment operates without interruption. An on-board ATS processor constantly evaluates the power quality of both input sources. It prevents switching if the secondary source is unavailable or of lower quality than the primary source.
Built-In LX Platform Network Management Card Allows Remote Access 24/7
The Java-free HTML5-based WEBCARDLX network interface enables full remote access for PDU status monitoring and email notifications via secure web browser, SNMP, telnet or SSH. The latest version of PowerAlert Device Manager (PADM20) provides enhanced remote management capabilities, including customizable dashboard graphs to fit user preferences. The PADM20 upgrade and Tripp Lite’s PowerAlert Element Manager (PAEM) form a powerful tool for expanding maintenance functions in large installations, including firmware update checks and backup and restoration of device configurations.
Digital Load Meter Helps Prevent Potentially Expensive Overloads
A digital ammeter reports the total load for all connected equipment. Monitoring amperage helps ensure load levels remain well below maximum capacity with no danger of overload that could lead to costly downtime or damaged equipment. Maintaining proper load levels, even while adding new equipment, can keep your TCO (total cost of ownership) low.
Mounts into 1U of Rack Space or on a Wall
Use the included mounting hardware to install the all-metal housing into 1U of space in an EIA-standard 19-inch rack. You may also use the mounting brackets to secure the PDU to a wall or under a counter.
TAA-Compliant for GSA Schedule Purchases
The PDUMNH20AT1 is compliant with the Federal Trade Agreements Act (TAA), which makes it eligible for GSA (General Services Administration) Schedule and other federal procurement contracts.
This monitored PDU provides real-time remote monitoring of voltage, frequency and load levels via its built-in network interface. Ideal for network IT applications, small computer rooms and other equipment rack applications, the PDUMNH20AT1 features 16 NEMA 5-15/20R 120V outlets for connecting equipment. Dual 12-foot (3.7-meter) power cords with NEMA L5-20P inputs (two 5-20P adapters are included) connect to separate primary and secondary mains circuits, backup generators, UPS systems or utility power grids, including out-of-phase sources.
Switches from Primary to Secondary Power Source in Milliseconds
Automatic transfer switching (ATS) allows the PDU to switch to the secondary source within 2–7 milliseconds, should the primary source fail or become unstable, to ensure your connected equipment operates without interruption. An on-board ATS processor constantly evaluates the power quality of both input sources. It prevents switching if the secondary source is unavailable or of lower quality than the primary source.
Built-In LX Platform Network Management Card Allows Remote Access 24/7
The Java-free HTML5-based WEBCARDLX network interface enables full remote access for PDU status monitoring and email notifications via secure web browser, SNMP, telnet or SSH. The latest version of PowerAlert Device Manager (PADM20) provides enhanced remote management capabilities, including customizable dashboard graphs to fit user preferences. The PADM20 upgrade and Tripp Lite’s PowerAlert Element Manager (PAEM) form a powerful tool for expanding maintenance functions in large installations, including firmware update checks and backup and restoration of device configurations.
Digital Load Meter Helps Prevent Potentially Expensive Overloads
A digital ammeter reports the total load for all connected equipment. Monitoring amperage helps ensure load levels remain well below maximum capacity with no danger of overload that could lead to costly downtime or damaged equipment. Maintaining proper load levels, even while adding new equipment, can keep your TCO (total cost of ownership) low.
Mounts into 1U of Rack Space or on a Wall
Use the included mounting hardware to install the all-metal housing into 1U of space in an EIA-standard 19-inch rack. You may also use the mounting brackets to secure the PDU to a wall or under a counter.
TAA-Compliant for GSA Schedule Purchases
The PDUMNH20AT1 is compliant with the Federal Trade Agreements Act (TAA), which makes it eligible for GSA (General Services Administration) Schedule and other federal procurement contracts.
Specifications
Design | |
---|---|
Type | Single-phase |
PDU types | Monitored, Switched |
Mounting | Horizontal |
Display | LCD |
Product colour | Black |
Rack capacity | 1U |
Housing material | Metal |
Ports & interfaces | |
USB ports quantity | 2 |
AC outlets quantity | 16 AC outlet(s) |
AC outlet types | NEMA 5-20R, NEMA 5–15 |
Power plug | NEMA L5-20P |
Serial ports quantity | 1 |
Ethernet LAN (RJ-45) ports | 1 |
Features | |
Cable length | 144.1" (3.66 m) |
LED indicators | Yes |
Ergonomics | |
Cable length | 144.1" (3.66 m) |
LED indicators | Yes |
Display | LCD |
Power | |
Maximum power | 2030 W |
Nominal input voltage | 120 V |
Nominal output voltage | 100 - 127 V |
Maximum current | 16 A |
AC input frequency | 50 - 60 Hz |
Weight & dimensions | |
Weight | 12.2 lbs (5.53 kg) |
Width | 17.5" (444.5 mm) |
Depth | 14.5" (368.3 mm) |
Height | 1.75" (44.4 mm) |
Package width | 23.3" (591.8 mm) |
Package depth | 20.1" (510.5 mm) |
Package height | 5.4" (137.2 mm) |
Package weight | 20.7 lbs (9.39 kg) |
Packaging data | |
Package width | 23.3" (591.8 mm) |
Package depth | 20.1" (510.5 mm) |
Package height | 5.4" (137.2 mm) |
Package weight | 20.7 lbs (9.39 kg) |
Packaging content | |
Cables included | AC |
Manual | Yes |
Rack mount kit | Yes |
Operational conditions | |
Storage temperature (T-T) | -30 - 50 °C |
Operating relative humidity (H-H) | 5 - 95% |
Operating altitude | 0 - 118110.2" (0 - 3000 m) |
Technical details | |
Sustainability compliance | Yes |
Compliance certificates | RoHS |
Logistics data | |
Products per master (outer) case | 1 pc(s) |
Country of origin | Taiwan |